Shop
Showing 1231–1260 of 1497 results
-
Oscilloscope 4 channles
Rigol MSO4034

350MHz, 4 channel, 4GS/s
MSO4000 Series is the new mainstream digital scope to meet the customer’s applications with its innovative technology, industry leading specifications, powerful trigger functions and broad analysis capabilities. – Bandwidth 350MHz – Sample Rate Analog channel up to 4 GSa/s, Digital Channel up to 1 GSa/s(MSO) – Standard Memory depth: Analog channel up to 140 Mpts, Digital Channel up to 28 Mpts(MSO) – 4 Analog Channels, 16 Digital channels(MSO) – Waveform capture rate Up to 110,000 waveforms per second, – Real Time Waveform Record, Replay & Analysis(Std. up to 200,000 frames) – Lower noise floor, the Min. vertical sensitivity is 1mV/div – Innovative “UltraVision” technology – A variety of Trigger functions – Support serial bus trigger(Std.) and decoding(Opt.) for both analog and digital channels – Complete Connectivity: USB Host& Device, LAN(LXI-C), VGA, AUX,USB-GPIB(Opt.) – 9 inch WVGA(800X480), 256 level intensity grading displaySKU: 728 -
Network Analyzer
HP/Agilent-Keysight 8753ES

Agilent 8753ES vector network analyzers perform complete characterization of RF components.
30 kHz to 3 GHz
Frequency and power sweepsSpecifications describe the instrument’s warranted performance after a half-hour warm-up and over the temperature range of 25° ± 5° C, unless otherwise stated. Specifications for frequencies above 3 GHz do not apply to instruments with Option 075 (75-ohm impedance). Supplemental characteristics are typical but nonwarranted performance parameters. These are denoted as “typical,” “nominal,” or “approximate.” The measurement uncertainty curves and measurement port characteristics given for Agilent Technologies 8753ES systems also apply to the 8753ES with Options 006 and 011 and the 85047A test set (50-ohm), or the 8753ES Option 011 with an 85046B test set (75-ohm).
System dynamic range is calculated as the difference between the receiver noise floor and the lesser of either the source maximum output or the receiver maximum input level. System dynamic range applies to transmission measurements only, since reflection measurements are limited by directivity. Noise floor is specified as the mean of the noise trace over frequency. Noise floor is measured with the test ports terminated in loads, full two-port error correction for the 8753ES and enhancedresponse error correction for the 8753ET (with 16 averages used during isolation), 10 Hz IF bandwidth (BW), maximum test port power, and no averaging during the measurement.
Measurement uncertainty curves utilize a Root Sum Square (RSS) model for the contribution of random errors such as noise, typical connector repeatabilities, and test set switching; this is combined with a worst-case model for the contributions of dynamic accuracy and residual systematic errors. Curves show the worst-case magnitude and phase uncertainty for reflection and transmission measurements, after a full two-port error correction for the 8753ES and enhanced-response error correction for the 8753ET (including isolation with an averaging factor of 16) using the specified cal kit, with 10 Hz IF bandwidth (BW) and no averaging.
Characteristics show the residual system uncertainties for uncorrected performance and after accuracy enhancement using full two-port error correction for the 8753ES and enhanced-response error correction for the 8753ET. These characteristics apply for an environmental temperature of 25° ± 5° C, with less than 1° C deviation from the calibration temperature. Agilent 8753ET Option 004 may degrade transmission source match as much as 2 dB, resulting in up to 0.05 dB additional uncertainty in transmission tracking. Corrected performance indicates residual error after calibration. It is determined by the quality of calibration standards, system repeatability, stability, and noise. Uncorrected performance indicates intrinsic errors without calibration correction applied. This is related to the ultimate stability of a calibration.
DatasheetSKU: n/a -
Microwave Network Analyzer
HP-Agilent/Keysight 85107B , 8510C , 85102B , 85101C , 8517B

HP 85107B 230 MICROWAVE NETWORK ANALYZER, 45 MHz to 50 GHz.
Complete with:
HP 8510C NETWORK ANALYZER
HP 85102B IF / DETECTOR
HP 8517B S-PARAMETER TEST SET 45 MHz-50GHz OPT 007
HP 85133-60016 2.4mm (f) FLEXIBLE TEST PORT CABLE Qty.2
HP 83651B SYNTHESIZED SWEEPER 10MHz – 50GHz 8360B Qty.1
ACCESSORIES:
Qty.1 INTELLIGENT INTERFACES MICROPRINT45CH VARIABLE RESOLUTION HP-GL / COLOR / SPEED MODES HP-IP TO PARALLEL INTERFACE CONVERTER;
Qty.1x WG K420 GPIB CABLE;
Qty.2x HP 10833A GPIB CABLE;
Qty.1x HP 08510-60101 IF INTERCONNECT DISPLAY;
Qty.1x HP 08510-60102 TEST SET – IF INTERCONNECT;
Qty.2x HP 10503A BNC CABLE;
Qty.1x HP 8710-1764 8lb-in;
Qty.1x HP 8710-1770 9/16 – 1/2;
Qty.1x HUBER & SUHNER SUCOFLEX 104P FLEXIBLE MICROWAVE CABLE ASSEMBLY;
Qty.5x ADAPTER.
DatasheetSKU: n/a
-
Oscilloscope 4 channles
Rigol MSO4034
350MHz, 4 channel, 4GS/s
MSO4000 Series is the new mainstream digital scope to meet the customer’s applications with its innovative technology, industry leading specifications, powerful trigger functions and broad analysis capabilities. – Bandwidth 350MHz – Sample Rate Analog channel up to 4 GSa/s, Digital Channel up to 1 GSa/s(MSO) – Standard Memory depth: Analog channel up to 140 Mpts, Digital Channel up to 28 Mpts(MSO) – 4 Analog Channels, 16 Digital channels(MSO) – Waveform capture rate Up to 110,000 waveforms per second, – Real Time Waveform Record, Replay & Analysis(Std. up to 200,000 frames) – Lower noise floor, the Min. vertical sensitivity is 1mV/div – Innovative “UltraVision” technology – A variety of Trigger functions – Support serial bus trigger(Std.) and decoding(Opt.) for both analog and digital channels – Complete Connectivity: USB Host& Device, LAN(LXI-C), VGA, AUX,USB-GPIB(Opt.) – 9 inch WVGA(800X480), 256 level intensity grading display -
-
Network Analyzer
HP/Agilent-Keysight 8753ES
Agilent 8753ES vector network analyzers perform complete characterization of RF components.
30 kHz to 3 GHz
Frequency and power sweepsSpecifications describe the instrument’s warranted performance after a half-hour warm-up and over the temperature range of 25° ± 5° C, unless otherwise stated. Specifications for frequencies above 3 GHz do not apply to instruments with Option 075 (75-ohm impedance). Supplemental characteristics are typical but nonwarranted performance parameters. These are denoted as “typical,” “nominal,” or “approximate.” The measurement uncertainty curves and measurement port characteristics given for Agilent Technologies 8753ES systems also apply to the 8753ES with Options 006 and 011 and the 85047A test set (50-ohm), or the 8753ES Option 011 with an 85046B test set (75-ohm).
System dynamic range is calculated as the difference between the receiver noise floor and the lesser of either the source maximum output or the receiver maximum input level. System dynamic range applies to transmission measurements only, since reflection measurements are limited by directivity. Noise floor is specified as the mean of the noise trace over frequency. Noise floor is measured with the test ports terminated in loads, full two-port error correction for the 8753ES and enhancedresponse error correction for the 8753ET (with 16 averages used during isolation), 10 Hz IF bandwidth (BW), maximum test port power, and no averaging during the measurement.
Measurement uncertainty curves utilize a Root Sum Square (RSS) model for the contribution of random errors such as noise, typical connector repeatabilities, and test set switching; this is combined with a worst-case model for the contributions of dynamic accuracy and residual systematic errors. Curves show the worst-case magnitude and phase uncertainty for reflection and transmission measurements, after a full two-port error correction for the 8753ES and enhanced-response error correction for the 8753ET (including isolation with an averaging factor of 16) using the specified cal kit, with 10 Hz IF bandwidth (BW) and no averaging.
Characteristics show the residual system uncertainties for uncorrected performance and after accuracy enhancement using full two-port error correction for the 8753ES and enhanced-response error correction for the 8753ET. These characteristics apply for an environmental temperature of 25° ± 5° C, with less than 1° C deviation from the calibration temperature. Agilent 8753ET Option 004 may degrade transmission source match as much as 2 dB, resulting in up to 0.05 dB additional uncertainty in transmission tracking. Corrected performance indicates residual error after calibration. It is determined by the quality of calibration standards, system repeatability, stability, and noise. Uncorrected performance indicates intrinsic errors without calibration correction applied. This is related to the ultimate stability of a calibration.
Datasheet -
Microwave Network Analyzer
HP-Agilent/Keysight 85107B , 8510C , 85102B , 85101C , 8517B
HP 85107B 230 MICROWAVE NETWORK ANALYZER, 45 MHz to 50 GHz.
Complete with:
HP 8510C NETWORK ANALYZER
HP 85102B IF / DETECTOR
HP 8517B S-PARAMETER TEST SET 45 MHz-50GHz OPT 007
HP 85133-60016 2.4mm (f) FLEXIBLE TEST PORT CABLE Qty.2
HP 83651B SYNTHESIZED SWEEPER 10MHz – 50GHz 8360B Qty.1
ACCESSORIES:
Qty.1 INTELLIGENT INTERFACES MICROPRINT45CH VARIABLE RESOLUTION HP-GL / COLOR / SPEED MODES HP-IP TO PARALLEL INTERFACE CONVERTER;
Qty.1x WG K420 GPIB CABLE;
Qty.2x HP 10833A GPIB CABLE;
Qty.1x HP 08510-60101 IF INTERCONNECT DISPLAY;
Qty.1x HP 08510-60102 TEST SET – IF INTERCONNECT;
Qty.2x HP 10503A BNC CABLE;
Qty.1x HP 8710-1764 8lb-in;
Qty.1x HP 8710-1770 9/16 – 1/2;
Qty.1x HUBER & SUHNER SUCOFLEX 104P FLEXIBLE MICROWAVE CABLE ASSEMBLY;
Qty.5x ADAPTER.
Datasheet
-
Oscilloscope 4 channles
Rigol MSO4034
350MHz, 4 channel, 4GS/s
MSO4000 Series is the new mainstream digital scope to meet the customer’s applications with its innovative technology, industry leading specifications, powerful trigger functions and broad analysis capabilities. – Bandwidth 350MHz – Sample Rate Analog channel up to 4 GSa/s, Digital Channel up to 1 GSa/s(MSO) – Standard Memory depth: Analog channel up to 140 Mpts, Digital Channel up to 28 Mpts(MSO) – 4 Analog Channels, 16 Digital channels(MSO) – Waveform capture rate Up to 110,000 waveforms per second, – Real Time Waveform Record, Replay & Analysis(Std. up to 200,000 frames) – Lower noise floor, the Min. vertical sensitivity is 1mV/div – Innovative “UltraVision” technology – A variety of Trigger functions – Support serial bus trigger(Std.) and decoding(Opt.) for both analog and digital channels – Complete Connectivity: USB Host& Device, LAN(LXI-C), VGA, AUX,USB-GPIB(Opt.) – 9 inch WVGA(800X480), 256 level intensity grading display -
-
Network Analyzer
HP/Agilent-Keysight 8753ES
Agilent 8753ES vector network analyzers perform complete characterization of RF components.
30 kHz to 3 GHz
Frequency and power sweepsSpecifications describe the instrument’s warranted performance after a half-hour warm-up and over the temperature range of 25° ± 5° C, unless otherwise stated. Specifications for frequencies above 3 GHz do not apply to instruments with Option 075 (75-ohm impedance). Supplemental characteristics are typical but nonwarranted performance parameters. These are denoted as “typical,” “nominal,” or “approximate.” The measurement uncertainty curves and measurement port characteristics given for Agilent Technologies 8753ES systems also apply to the 8753ES with Options 006 and 011 and the 85047A test set (50-ohm), or the 8753ES Option 011 with an 85046B test set (75-ohm).
System dynamic range is calculated as the difference between the receiver noise floor and the lesser of either the source maximum output or the receiver maximum input level. System dynamic range applies to transmission measurements only, since reflection measurements are limited by directivity. Noise floor is specified as the mean of the noise trace over frequency. Noise floor is measured with the test ports terminated in loads, full two-port error correction for the 8753ES and enhancedresponse error correction for the 8753ET (with 16 averages used during isolation), 10 Hz IF bandwidth (BW), maximum test port power, and no averaging during the measurement.
Measurement uncertainty curves utilize a Root Sum Square (RSS) model for the contribution of random errors such as noise, typical connector repeatabilities, and test set switching; this is combined with a worst-case model for the contributions of dynamic accuracy and residual systematic errors. Curves show the worst-case magnitude and phase uncertainty for reflection and transmission measurements, after a full two-port error correction for the 8753ES and enhanced-response error correction for the 8753ET (including isolation with an averaging factor of 16) using the specified cal kit, with 10 Hz IF bandwidth (BW) and no averaging.
Characteristics show the residual system uncertainties for uncorrected performance and after accuracy enhancement using full two-port error correction for the 8753ES and enhanced-response error correction for the 8753ET. These characteristics apply for an environmental temperature of 25° ± 5° C, with less than 1° C deviation from the calibration temperature. Agilent 8753ET Option 004 may degrade transmission source match as much as 2 dB, resulting in up to 0.05 dB additional uncertainty in transmission tracking. Corrected performance indicates residual error after calibration. It is determined by the quality of calibration standards, system repeatability, stability, and noise. Uncorrected performance indicates intrinsic errors without calibration correction applied. This is related to the ultimate stability of a calibration.
Datasheet -
Microwave Network Analyzer
HP-Agilent/Keysight 85107B , 8510C , 85102B , 85101C , 8517B
HP 85107B 230 MICROWAVE NETWORK ANALYZER, 45 MHz to 50 GHz.
Complete with:
HP 8510C NETWORK ANALYZER
HP 85102B IF / DETECTOR
HP 8517B S-PARAMETER TEST SET 45 MHz-50GHz OPT 007
HP 85133-60016 2.4mm (f) FLEXIBLE TEST PORT CABLE Qty.2
HP 83651B SYNTHESIZED SWEEPER 10MHz – 50GHz 8360B Qty.1
ACCESSORIES:
Qty.1 INTELLIGENT INTERFACES MICROPRINT45CH VARIABLE RESOLUTION HP-GL / COLOR / SPEED MODES HP-IP TO PARALLEL INTERFACE CONVERTER;
Qty.1x WG K420 GPIB CABLE;
Qty.2x HP 10833A GPIB CABLE;
Qty.1x HP 08510-60101 IF INTERCONNECT DISPLAY;
Qty.1x HP 08510-60102 TEST SET – IF INTERCONNECT;
Qty.2x HP 10503A BNC CABLE;
Qty.1x HP 8710-1764 8lb-in;
Qty.1x HP 8710-1770 9/16 – 1/2;
Qty.1x HUBER & SUHNER SUCOFLEX 104P FLEXIBLE MICROWAVE CABLE ASSEMBLY;
Qty.5x ADAPTER.
Datasheet


Italiano

























